'CR800 Series Datalogger 'Pumping sampler test program 'Attempts to activate either Sampler 1 or Sampler 2 every 3 min. 'Set Flag 1 to activate ISCO 1, deactivate Flag 1 to turn off 'Set Flag 2 to activate ISCO 2, deactivate Flag 2 to turn off 'Connect sampler 1 to Port 2 (C2), via flow connector 'Connect sampler 2 to Port 3 (C3), via flow connector 'Sampler must be set to Flow mode, 1 pulse per sample 'Date: 4/27/2007 'Program author: R. Eads, RiverMetrics LLC '\\\\\\\\\\\\\\\\\\\\\\\\\ DECLARATIONS ///////////////////////// PreserveVariables Public Flag(2) as BOOLEAN '\\\\\\\\\\\\\\\\\\\\\\\\\\\ MAIN PROGRAM //////////////////////////// BeginProg SequentialMode Scan(3,Min, 3, 0) If Flag(1) = True Then 'Pulse Port 2 to trigger pump sampler on C2 PortSet(2,1) Delay(0,100,mSec) PortSet(2,0) Else If Flag(2) = True Then 'Pulse Port 3 to trigger second pump sampler on C3 PortSet(3,1) Delay(0,100,mSec) PortSet(3,0) EndIf NextScan EndProg '\\\\\\\\\\\\\\\\\\\\\\\\\\\ END MAIN PROGRAM ////////////////////////////